Add to cart
cart
(0)
Shopping cart
There are no products in your cart.
Free shipping and free change for all orders.
Products value0 €

Fractional Laser eCO2 Plus Bella-V with Gynecology Handpieces Bella-V 360 and Bella-V 90 by Cynosure Lutronic Fractional Laser eCO2 Plus Bella-V with Gynecology Handpieces Bella-V 360 and Bella-V 90 by Cynosure Lutronic
Fractional Laser eCO2 Plus Bella-V with Gynecology Handpieces Bella-V 360 and Bella-V 90 by Cynosure Lutronic

Fractional Laser eCO2 Plus Bella-V with Gynecology Handpieces Bella-V 360 and Bella-V 90 by Cynosure Lutronic

Code: 12186
Manufacturer Ref: eCO2 Plus BELLA-V
Description:

The Leading eCO2 Plus BELLA-V Laser on the Market!
Includes 2 Gynecological Handpieces:
360 Degree HP Suitable for vaginal tightening
90 Degree HP Suitable for the treatment of urinary incontinence

Availability:
Temporarily unavailable
Delivery time: Delivery up to 30 days
I am interested
print product to pdf
print product to pdf
  • Description
  • Videos

Videos

Description

Blank page

Fractional Laser eCO2 Plus Bella-V by Lutronic with RF Tube with gynaecology handpieces
Dual Mode CO2 Resurfacing Laser
Uncovering Youth One Patient at A Time
Lutronic’s eCO2 is the premier fractional ablative laser that delivers the full spectrum of resurfacing treatments to your busy practice. You will appreciate how easy to use and reliable the system is while your patients rave about their outcomes.
The eCO2 features the patented Controlled Chaos Technology (CCT™) an algorithm to pseudo-randomly deliver each micro laser beam and by placing maximum distance between sequential beams the system eliminates cross thermal diffusion between adjacent Micro-ablative Columns (MACs).
This allows the tissue to maximize heat dissipation between shots. The result is an increased safety profile with a reduction in post-operative discomfort and faster healing time leading to unparalleled fractional resurfacing results.

Full range of Applications
Skin Tightening
Wrinkles, Rhytids & Fine Lines
Pigmented Lesions & Lentigines
Scars (e.g.: acne scar, surgical scar, burn scar)*
Textural Irregularities
Transepidermal Drug Delivery
Dyschromia
Solar/Actinic Elastosis
Syringoma*
Vaporization, Incision & Excision Capabilities

With Auto recognition you can change Tips very Quick and easy
The eCO2 sets itself apart from the competition with ultra deep ablation depths.
eCO2 is proven to deliver up to 2.4 mm of ablation depth.

From ultra-deep to superficial ablation, the eCO2 has the features you need to address a broad range of clinical conditions. The ultra-fast quick change tips come in a choice of three spot sizes 120, 300 and 500 μm allowing you on-the-fly customized treatments. The eCO2’s tip auto-recognition feature automatically changes treatment settings to adjust for the change in spot size. Combined together, the advanced technology, quick-change tips and safety features ensure the ultimate control for the best outcomes.

120 μm spot
Deep epidermal penetration
Coverage per pass: 1-17%
Fast healing time
Scarring
Deep wrinkles and skin tightening

300
μm spot
Medium epidermal penetration
Coverage per pass: 5–58%
Large pores
Skin regeneration
Luminosity

500
μm spot
Superficial epidermal penetration
Coverage per pass: 20–130%
Skin regeneration
Brightness

Technical Specifications
Wavelength: 10.6
μm
Beam delivery system: Articulated arm with scanner or standard handpiece
Maximum power: 30 Watts (continuous wave)


Fractional Handpiece
Operating modes: Static (Stamping) / Dynamic (Air Brushing)
Interchangeable tips: 120, 300 & 500
μm
Pulse energy: 2 mJ - 240 mJ
Pulse rate: 10 Hz - 200 Hz
Density: 25 - 400 spots/cm²
Coverage area: 18 x 18 mm
Shapes: Square, Rectangle, Ellipse, Triangle, Dot

2 Handpieces for Gynecology eCO2 Laser by Lutronic:
360 Degree HP: Suitable for vaginal tightening
90 Degree HP: Suitable for the treatment of urinary incontinence

BellaV360°Reflector
27 Fractional Beam at 360 Degree HP
Each Beam Diameter: 500um

BellaV90°Reflector
18 Fractional Beam at 90 Degree HP
Each Beam Diameter: 500um

The reflectivity of gold is 96.2%.
In case of titanium reflector, its reflectivity is only 69.3%.
The rest of 30.7% remains inside the reflector as heat. It could burn skin.
Non surgical eCO2 treatment with the 90 handpiece through the vaginal canal offers a thermal and shrinkage effect on the endopelvic fascia / ligament (2 o’clock & 10 o’clock) and mucosal tissue (12 o’clock) of the anterior vaginal canal to improve urinary incontinence.

Treatments:
Stress urinary incontinence
Post-menopausal atrophy
Post radiation dryness
Labia rejuvenation
Vaginal tightening
Vestibule & Introitus Tightening
Pigmented Vulva


Specification:
User Mode:Bella V
Pulse Energy:2mJ ~ 240mJ
Scan Area:4x4mm(360 Degree), 6x6 mm(90 Degree)
Density:50 spots/cm2

Recently viewed
×
Invalid Input

Invalid Input

Required field

Required field

Invalid Input

Required field

Invalid Input

Invalid Input

×
Invalid Input

Invalid Input

Required field

Required field

Invalid Input

Required field

Invalid Input

Invalid Input


Newsletter
top